 "categories": [
  "healthcare",
  "clinical"
 ],
 "deployment": "desktop",
 "evidence": [
  {
   "date": "2026-09-13",
   "fact": "homepage",
   "note": "Sectra presents IDS7 as a single-login diagnostic application that unifies imaging workflows, built-in tools, and third-party viewers for radiology and other specialties.",
   "source": "https://medical.sectra.com/product/sectra-ids7/",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "vendor",
   "note": "The product page is published on medical.sectra.com by Sectra Medical.",
   "source": "https://medical.sectra.com/product/sectra-ids7/",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "deployment",
   "note": "IDS7 is described as a diagnostic application with workstation settings, remote work over the healthcare network, and launch of Windows default apps. That is a desktop client, not a self-serve SaaS console.",
   "source": "https://medical.sectra.com/product/sectra-ids7/",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "platforms",
   "note": "The page names Windows default apps for file launch and workstation administration. No macOS or Linux client is named on the opened product page.",
   "source": "https://medical.sectra.com/product/sectra-ids7/",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "license",
   "note": "Third-party software is excluded unless specified in the contract, and reporting availability is sales-gated. That is a commercial clinical product.",
   "source": "https://medical.sectra.com/product/sectra-ids7/",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.api.exists",
   "note": "Sectra's official URL Launch SDK documents a protocol for launching Sectra products and passing patient and study context through URL parameters.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.api.kinds[0]",
   "note": "The documented interface is URL-based launch commands, not a CRUD REST catalogue.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.api.kinds[1]",
   "note": "The 28.1.0 DICOM Conformance Statement covers Sectra PACS. Section 3.1.1.1 states IDS7 itself does not contain network DICOM Application Entities; IDS7 commands can trigger DICOM communication through server components.",
   "source": "https://medical.sectra.com/wp-content/uploads/sites/3/2026/03/dicom.conformancestatement.sectrapacs-28.1.0.10183.pdf",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.api.auth[0]",
   "note": "Shared Secret encryption uses a 32-byte key shared with the Sectra system. The algorithm includes a timestamp valid for 30 seconds.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.api.auth[1]",
   "note": "PKI encryption uses certificate-based asymmetric encryption with one certificate for the integrator and one for the Sectra system.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.api.coverage",
   "note": "URL Launch starts modules and passes context. The README states the API is fire-and-forget and does not automatically keep the caller in sync. That is a narrow launch path, not a write API for reports or worklists.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.api.docs",
   "note": "Opened the official sectra-medical/SectraUrlLaunchSdk repository as the public URL Launch contract.",
   "source": "https://github.com/sectra-medical/SectraUrlLaunchSdk",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.sdk.exists",
   "note": "Sectra publishes the URL Launch SDK as NuGet packages Sectra.UrlLaunch.SharedSecret and Sectra.UrlLaunch.UrlAccessString, built with the latest .NET LTS SDK.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.sdk.languages[0]",
   "note": "The documented SDK language is .NET / C#.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.extensibility.scripting[0]",
   "note": "URL Launch is the documented partner scripting mechanism for starting Sectra workflows from another application.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.extensibility.scripting[1]",
   "note": "The enterprise imaging platform page names a Web Content API among DICOM, HL7, XDS, and FHIRcast. No public OpenAPI for that API was opened on this pass.",
   "source": "https://medical.sectra.com/solutionarea/enterprise-imaging-platform/",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.data_access.export[0]",
   "note": "Sectra PACS supports DICOM Storage as SCU (export) for the listed SOP classes. IDS7 viewing support is tabulated separately from network AEs.",
   "source": "https://medical.sectra.com/wp-content/uploads/sites/3/2026/03/dicom.conformancestatement.sectrapacs-28.1.0.10183.pdf",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.data_access.import[0]",
   "note": "The same statement supports DICOM Storage as SCP (import) for those SOP classes at the PACS, not as an IDS7-local network AE.",
   "source": "https://medical.sectra.com/wp-content/uploads/sites/3/2026/03/dicom.conformancestatement.sectrapacs-28.1.0.10183.pdf",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "modalities.agent_docs.llms_txt",
   "note": "https://medical.sectra.com/llms.txt returned 404 on 2026-09-13.",
   "source": "https://medical.sectra.com/llms.txt",
   "tier": "scraped"
  },
  {
   "date": "2026-09-13",
   "fact": "verdict.scores.api",
   "note": "An official launch SDK exists, but it is context-passing and partner-configured, with no public REST catalogue for the workstation. That is a usable, narrow, operationally gated path.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "freshness.watch[0].url",
   "note": "Opened and verified as the current IDS7 product page, including DICOM viewing, embedded web content, and third-party tool integration.",
   "source": "https://medical.sectra.com/product/sectra-ids7/",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "freshness.watch[1].url",
   "note": "Opened and verified as the current enterprise imaging platform interoperability list: DICOM, HL7, XDS, Web Content API, FHIRcast.",
   "source": "https://medical.sectra.com/solutionarea/enterprise-imaging-platform/",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "freshness.watch[2].url",
   "note": "Opened and verified as the current URL Launch SDK README, including shared-secret and PKI encryption.",
   "source": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md",
   "tier": "declared"
  },
  {
   "date": "2026-09-13",
   "fact": "freshness.watch[3].url",
   "note": "Opened and verified as the current 28.1.0 Sectra PACS DICOM Conformance Statement, including the IDS7-has-no-network-AE clause.",
   "source": "https://medical.sectra.com/wp-content/uploads/sites/3/2026/03/dicom.conformancestatement.sectrapacs-28.1.0.10183.pdf",
   "tier": "declared"
  }
 ],
 "freshness": {
  "last_verified": "2026-09-13",
  "volatility": "low",
  "watch": [
   {
    "type": "docs",
    "url": "https://medical.sectra.com/product/sectra-ids7/"
   },
   {
    "type": "docs",
    "url": "https://medical.sectra.com/solutionarea/enterprise-imaging-platform/"
   },
   {
    "type": "repo",
    "url": "https://raw.githubusercontent.com/sectra-medical/SectraUrlLaunchSdk/main/README.md"
   },
   {
    "type": "docs",
    "url": "https://medical.sectra.com/wp-content/uploads/sites/3/2026/03/dicom.conformancestatement.sectrapacs-28.1.0.10183.pdf"
   }
  ]
 },
 "homepage": "https://medical.sectra.com/product/sectra-ids7/",
 "id": "sectra-ids7",
 "license": "commercial",
 "modalities": {
  "agent_docs": {
   "llms_txt": false
  },
  "api": {
   "auth": [
    "shared-secret",
    "pki"
   ],
   "coverage": "partial",
   "docs": "https://github.com/sectra-medical/SectraUrlLaunchSdk",
   "exists": true,
   "kinds": [
    "url-launch",
    "dicom"
   ]
  },
  "cli": {
   "exists": "unknown"
  },
  "computer_use": {
   "issues": [],
   "viability": "unknown"
  },
  "data_access": {
   "export": [
    "dicom"
   ],
   "import": [
    "dicom"
   ]
  },
  "extensibility": {
   "scripting": [
    "url-launch",
    "web-content-api"
   ],
   "webhooks": "unknown"
  },
  "integrations": {
   "make": "unknown",
   "n8n": "unknown",
   "power_automate": "unknown",
   "zapier": "unknown"
  },
  "mcp": {
   "first_party": "unknown",
   "third_party": [],
   "verdict": "unknown"
  },
  "rpa": {
   "drivability": "unknown",
   "notes": "No repeatable UI probe was run. IDS7 is a diagnostic Windows workstation. The documented machine paths are URL Launch and PACS-level DICOM, HL7, XDS, Web Content API, and FHIRcast, not unattended clicking of a reporting session. Clinical safety and patient privacy still govern every launch.\n",
   "ui_stack": [
    "windows-desktop"
   ],
   "vendor_support": []
  },
  "sdk": {
   "exists": true,
   "languages": [
    "dotnet"
   ],
   "official": true
  }
 },
 "name": "Sectra IDS7",
 "platforms": [
  "windows"
 ],
 "related": {
  "alternatives": [
   "cambio-cosmic",
   "dips"
  ],
  "our_products": []
 },
 "schema_version": 1,
 "score_version": 1,
 "status": "active",
 "vendor": "Sectra",
 "verdict": {
  "best_path": "api",
  "scores": {
   "api": 4,
   "cli": null,
   "computer_use": null,
   "integrations": null,
   "mcp": null,
   "overall": 4,
   "rpa": null
  },
  "summary": "Sectra IDS7 is automatable today only as a launched diagnostic workstation and as a consumer of PACS interoperability, not as a public REST admin API. The official Sectra URL Launch SDK builds encrypted query strings that start Sectra products with user, patient, and study context. Shared-secret launches use a 32-byte key and expire after 30 seconds; PKI uses paired certificates. The vendor states the URL launch API is fire-and-forget and does not keep the caller in sync. The Sectra PACS DICOM Conformance Statement 28.1 (March 2026) says IDS7 itself has no network DICOM Application Entities; commands in IDS7 can trigger DICOM through Sectra Healthcare Server and related PACS components. The enterprise imaging platform page names DICOM, HL7, XDS, Web Content API, and FHIRcast as integration interfaces. Those platform contracts are customer- and partner-configured; this pass did not open a public Web Content API reference. UniView, VNA, and Sectra One Cloud are outside this record. First-party MCP ownership is not established. Computer-use viability is unassessed. API scores 4 and is the best path.\n"
 }
}